Case analysis of defective harness forming
One. Scorch Phenomenon characteristics: high-temperature control, temperature control instrument failure (such as poor contact of thermoelectric Europe). b. The gum is very smoky, with a strong smell and a crunchy sound. C. Middle coke-like coke. d. Cracks and pores in the glued joint Cause: The temperature control is too high. b. The scorch on the screw has not been cleaned for a long time. C. After a long shutdown, the plastic in the screw will age and decompose. d. If the heating time is too long, the plastic in the screw will age and decompose. e. Change the mold multiple times and change the color to break down the plastic. F. The gland of the machine head is loose, and the rubber material in the clamping channel is kept for a long time, causing aging and decomposition. G. Instrument malfunction. Solution: Check the heating system. b. Clean the machine head and tighten the screws regularly. C. According to the process of heating, pay attention to the time. d. Change the...